VARILITE® - VIRTUOSO™ / VIRTUOSO™ DX CONSOLE USERS MANUAL
310 23-Sep-02 02.9651.0001 C
If the Timecode Autoswitch is enabled, the system will continue executing events
in the normal sequence using its internal time clock, until the system can resync.
At that point, the external time clock will take over again and the internal clock
will sync to those values.
If the Timecode Autoswitch is disabled, the system will stop executing events until
timecode is resynced. After resyncing, execution of events will resume.
Recording
Timecode is recorded using the Timecode window. The timecode and corresponding
event steps are stored in a Timecode Script which can be viewed and edited using the
Timecode Scripts window (refer to next page). Unless a different script number is
selected in the window, the script will be stored as Number 1 by default. To record
timecode into a script other than 1, select its number at the Timecode Scripts window.
Record Timecode:
Step 1. At Operation menu, select Time Code. Timecode
window will open.
Step 2. Select External or Internal.
Step 3. Select a frame rate.
Step 4. Click record button to begin timed recording. Clock
will start counting.
Step 5. Execute cues.
Step 6. Click stop button.
Play Stop